Output Selections Table

WARNING: Access Control related outputs can only be used
with the addition of the “Feature Expansion Board”.

Program Section (“q”)

“S”ystem

Section Range (“nnn”)

000 – 000

Code

cc

Description

00

Fallback sonalert (at control panel) if
Module Bus fails. Provides 1 sec. Output
every 8 sec. And activates if there is no
operational keypad in an area with
programmed keypads.

01 Not

Used

02

When system is FULLY ON

03

PARTIALLY ON. One or more areas
ON.

04

When system is FULLY OFF

05

When system is IN ALARM - resets
when point(s) restore
(includes pseudos & tampers)

06

Follows ALARM (BURG / EMERG) &
FIRE siren steady.

07

Follows ALARM siren - steady for BURG
/ EMERG. Keypad tone & siren is 1 sec
on/off for FIRE.
For UL: When using this output type,
fire siren is ½ sec on/off three times, 1.5
sec pause, and repeats. Keypad tone is
1 sec on/off.

08

Follows ALARM siren - steady for BURG
/ EMERG and provides 2 sec on/off for
FIRE

09

Digital PHONE LINE trouble (follows
report delay or line failure)

10

System WAS IN ALARM. This is only for
input points in alarm e.g. NOT for
system trouble (clears when alarmed
areas are turned off then back on again)

11

When there is a point BYPASSED
somewhere in the system

12

When any ‘FIRE’ point is in alarm

13

When any ‘HOLD UP’ point is in alarm

14

When any ‘Aux Alert' point is in alarm

15

When any ‘VAULT / SAFE’ type point is
in alarm

16

When any ‘'Burglary' point is in alarm.
Delayed burglary for European
Version.

17

When any ‘Supervisory' point is in alarm.

18

When any 'Pseudo' is in alarm

19

Pseudo 1 – System Trouble / All type
tamper for European Version.

20

Pseudo 2 – Battery Trouble

21

Pseudo 3 – AC (Mains) Trouble

22

Pseudo 4 – Phone Trouble

23

Pseudo 5 – Report Delay

24

Pseudo 6 – Time Lost

25

Pseudo 7 – Time Change

26

Pseudo 8 – Program Change

27

Pseudo 9 – Program Error

28

Pseudo 10 – Fuse Failure


29

Pseudo 11 – Module Trouble

30

Pseudo 12 – Module Battery Low

31

Pseudo 13 – Module Program Edit

32

Pseudo 14 – Module Program Error

33

Pseudo 15 – Misc. Trouble

34

Pseudo 16 – SIP Trouble

35 Duress

Pin

36 Doors

Unlocked.

37

Doors Locked Out

38 Doors

Held

Open

39 Doors

Forced

40

Doors Tamper (door contact condition:
no EOL resistor etc.)

41 Doors

Open

42 Doors

Secure

43

Doors Sensor Trouble (magnetic bond
sensor not ok)

44

Global Invalid PIN and / orCard lockout.

45

Host (Director) computer is On-Line.

46

Host (Director ) computer is Off-Line.
Response time for IP, external modem,
direct connection is 2 min. Bell 103 is 1
min.

47 SIP

On-Line.

48

SIP Off-Line. Response time is 3
minutes.

49

Any point in tamper.

50

Any point in Alarm.

51

Any area is Force Arming

52

Any area Failed to Close

53

Phone Line Failure

54

Local AC (mains) failure.

55

System Tamper – European Version.

56

System Fault – European Version.

57

System WAS IN ALARM. This is only for
input points in alarm e.g. NOT for
system trouble (clears when alarmed
areas are turned off)

58

Bypass is in effect in any armed area.

European

Version (System)

59 Fire
60 Personal

Attack

61 Unconfirmed

Alarm

62

Area Set / Unset

63

Freezer / Fire Fault

64

Bypass in Effect

65 Confirmed

Alarm

66 Siren
67 Confirmed

Alarm

(Strobe)

System Special Outputs. Section Range: 001 – 001. See
examples 8 & 9 in Output Examples. NOTE: Only
configurable through the Director Software.

00

1 sec on, 1 sec off

01

2 seconds on every minute

02

10 seconds on every minute