Interlogix Monitor XL Advanced Installation Guide User Manual

Page 68

Advertising
background image

62

Monitor xL™ Advanced Installation Guide

21-3602E rev1.5

(CID codes--continued from preceding page)

E354

UX0

Digital Dialer Comms Failure (Messages Lost), or; Emergency

RO

Misc Trouble (E015)

Emergency

E356

UX1

Security IP Comms Failure (Messages Lost, Sync Lost, Reset)

Emergency




E380

FT

Fire Class A--Tamper, or; Emergency

FT

Fire--Tamper, or; Emergency

PT

Holdup--Tamper, or; Emergency

MT

Aux. Alert--Tamper, or; Emergency

QT

Vault/Safe--Tamper, or; Emergency

UT

Misc/No Type--Tamper, or; Emergency

RB

Module Program Changed (E013), or; Emergency

E383

BT

Burglary --Tamper

Emergency

E384

XT

Module Battery Low--e.g. wireless transmitter (E012)

Emergency

E401

OP

Turn Area Off

Full

E404

JR

Schedule resumed (Stay opened resume)

Emergency

E405

CE

Work late (Closing extended)

Emergency

E409

OA

Automatic Area Off (SDC5 type points)

Full

E422

DG

Second User Authority Granted for Dual Custody

Full

E450

OR

Unauthorized Off (schedules)

Emergency

E451

OK

Emergency Off (schedules)

Emergency

E453

CI

Fail to Turn Area On (Fail to Close)

Emergency

E458

DU

Verify User

Emergency

E459

JS

Schedule suspended (Stay opened suspended)

Emergency

E602

UX2

Digital Dialer Comms Test

Emergency

E607

TS

Walk or Holdup Test Started (no msg at end of test)

Emergency

E625

JT

Time Changed (E007)

Emergency

R100

MR

Aux. Alert--Restore

Emergency

R110

FR

Fire or Fire-Class A--Restore

Emergency

R120

PR

Holdup--Restore Emergency

R120 or PR with event code
199” for Monitor ISM and
299” for Monitor xL

Global Lockout Alarm Restore (caused by invalid card/PIN use in Area).

Emergency

R130

BR

Burglary --Restore

Emergency

R140

QR

Vault/Safe--Restore Emergency

R143

ER

Module tamper/comms/subst'n (E011--Restore)

Emergency

R145

RS

Module Program Error (E014--Restore)

Emergency

R150

UR

Misc/No Type--Restore

Emergency

R300

TR

Main panel Tamper (E001--Restore)

Emergency

R301

AR

AC Trouble (E003--Restore)

Emergency

R306

LX

Main panel Config Changed (E008--Restore)

Emergency

R309

YR

No/Low battery (E002--Restore)

Emergency

R320

YQ

Main panel Fuse Failure (E010--Restore)

Emergency

R330

LS

Main panel Program Error (E009--Restore)

Emergency

R333

YK

Security IP Comms Trouble (E016--Restore) Emergency

R351

LR

Phone Trouble (E004--Restore)

Emergency

R354

RC

Misc Trouble (E015--Restore)

Emergency

R380

RN

Module Program Changed (E013--Restore)

Emergency

R384

XR

Module Battery Low--e.g. wireless transmitter (E012--Restore)

Emergency

R401

CL

Turn Area On (Normal)

Full

R402

CF

Turn Area On (Bypass or Forced)

Full

R403

CA

Automatic Area On (Sched. auto-arm on fail to close)

Full

R407

NK+

Emergency Stay Out of Schedule

Emergency

R408

NL

Turn Area to Stay (Normal)

Full

R441

OG

Turn Area to Stay from On

Full

R456

NF

Turn Area to Stay (Bypass or Forced)

Full

R457

NR+

Unauthorized Stay If No Emergency Off

Emergency

Advertising