3 digital i/o connection – ADLINK cPCI-9116 User Manual

Page 28

Advertising
background image

18

• Signal Connections

User Common Mode (U_CMMD)

To measure ground-referenced signal sources, which are connected to the
same ground point, you can connect the signals in a User-Common-Mode
(U_CMMD) configuration. Fig 7 illustrates the connections. The signal local
ground reference is connected to the negative input of the instrumentation
Amplifier, and the common-mode ground potential to signal ground. The
instrumentation amplifier will now reject the 9116 series ground.

AIn

U_CMMD

n = 0, ...,63

Ground-
Referenced
Signal Source

Instrumentation
Amplifier

To A/D
Converter

Input Multipexer

V1

V2

+

-

+

-

V

cm

Common-
mode noise &
Ground
potential

Figure 7: Ground-referenced source and User Common Mode connections

3.3 Digital

I/O

Connection

The 9116 series card provides 8 digital input and 8 digital output channels. The
digital I/O signals are fully TTL/DTL compatible. The details of the digital I/O
signal specification can be found in section 1.3.

Digital Input(DI)

74LS244

From TTL Signal

To TTL Devices

Digital Output(DO)

Digital GND(DGND)

74LS244

Figure 8: Digital I/O Connection