9 digital i/o register – ADLINK cPCI-9116 User Manual

Page 39

Advertising
background image

Registers

• 29

4.9

Digital I/O register

There are 8 digital input and 8 digital output channels provided by the 9116
series cards. The address Base + 30 is used to access digital inputs and
control digital outputs.

Address: BASE +30

Attribute: read

Data Format:

Bit

7

6

5

4

3

2

1

0

DI7 DI6 DI5 DI4 DI3 DI2 DI1 DI0

Bit

15

14

13

12

11

10

9

8

DO7 DO6 DO5 DO4 DO3 DO2 DO1 DO0

Bit

23

22

21

20

19

18

17

16

--- --- --- --- --- --- --- ---

Bit

31

30

29

28

27

26

25

24

--- --- --- --- --- --- --- ---

Table 12. Digital I/O register (Read)

Address: BASE + 30

Attribute: write

Data Format:

Bit

7

6

5

4

3

2

1

0

DO7 DO6 DO5 DO4 DO3 DO2 DO1 DO0

Bit

15

14

13

12

11

10

9

8

--- --- --- --- --- --- --- ---

Bit

23

22

21

20

19

18

17

16

--- --- --- --- --- --- --- ---

Bit

31

30

29

28

27

26

25

24

--- --- --- --- --- --- --- ---

Table 13. Digital I/O register (Write)