• Operation Theory

Mode 0: Interrupt on Terminal Count

Mode 0 is typically used for event counting, as illustrated in fig 20. After the
initial count is written, OUT is initially low, and will remain low until the Counter
counts to zero. OUT then goes high and will remain high until a new count is
written into the Counter.

3

3

2

1

1

1

0

0

0

Gate

CLK

Count value

OUT

Mode 0, Initial count=3, Count down

Figure 20: Mode 0 Operation

Mode 1: Rate Generator

This mode operates like a divide-by-N counter, as illustrated in fig 21. After the
initial count is written, initially OUT is low. When the counter reaches 1, OUT
goes high for one clock pulse. OUT then goes low again. The counter reloads
the initial count and the process will be repeated.

3

3

2

2

1

3

2

1

3

Gate

CLK

Count value

OUT

mode 1, Initial count=3, Count down

Figure 21: Mode 1 Operation

Note:

In Mode 1 the initial count value N must be larger than one.