• Registers

ACQ (Bit7):

Read Only, set when acquisition is in progress.

Full (Bit6):

Read Only A/D FIFO Full status (Fatal Error!)

0: FIFO Full

1: FIFO not Full

HFull(Bit5):

Read only A/D FIFO Half Full status

0: FIFO Half Full

1: FIFO not Half Full

Empty (Bit4): Read Only A/D FIFO Empty status

0: FIFO Empty

1: FIFO not Empty

Trg_det (Bit3): Read/ Write 1 to clear External Digital Trigger Status

1: External Digital Trigger

0: No External Digital Trigger

SC_TC(Bit2): Read/ Write 1 to clear Scan Counter Terminal Count Status

1: Scan Counter counts to 0

0: Scan Counter not completed

ADOR(Bit1):

Read/ Write 1 to clear A/D Overrun Status (Fatal Error !)

1: A/D Overrun

0: A/D not Overrun

ADOS(Bit0):

Read/ Write 1 to clear A/D Over Speed Status (Warning !)

1: A/D Over Speed

0: A/D not Over Speed