Registers

• 21

4.2

Internal Timer/Counter Register

The 9116 series card basically has 6 counters, which are responsible for the
scan timing of the analog input data acquisition. The 6 counters occupy 6 I/O
address locations in the 9116 card as shown below.

Address: BASE + 0 ~ BASE + 14

Attribute: read / write

Data Format:

Base + 0x00

Scan Interval Counter Register (R/W) 24bit

Base + 0x04

Sample Interval Counter Register (R/W) 16bit

Base + 0x08

Scan Counter Register (R/W) 24bit

Base + 0x0C

DIV Counter Register (R/W) 9bit

Base + 0x10

Delay1 Counter Register (R/W) 16bit

Base + 0x14

M Counter Register (R/W) 16bit

Table 3. Timer/Counter Register Address

SI_counter:

Scan Interval counter

SI2_counter:

Sample Interval counter

SC_counter:

total Scan Count counter

DIV_counter:

specify the number of samples per scan

DLY1_counter: Delay

Interval

counter (only used in delay trigger mode)

M_counter:

specify the number of scans before a trigger (only used in
pre-trigger and middle-trigger modes)