64

• C++ Library

6.8

AD Counter setting functions

These functions are for the setting of the counter values when using
programmable scan acquisition mode. Refer to Chapter 5 for definition
of each counter.

6.8.1 _9116_AD_Set_SC

@ Description

Set SC_Counter value for programmable scan acquisition mode.

@ Syntax

C/C++ (DOS)

int _9116_AD_Set_SC( I16 card_number, U32 counter_value )

@ Argument

card_number:

the card number of the cPCI-9116 to be initialized,
totally 4 cards can be initialized, valid card
numbers are CARD_1, CARD_2, CARD_3,
CARD_4.

Counter_value:

the SC_Counter value. Range: 1 through to
16777215

@ Return Code

ERR_NoError
ERR_BoardNoInit