Controlling a Street Lighting Network

shortcut menu. The Cleanup dialog opens. Click Cleanup to reset

the Segment Controller.

To restore your Segment Controller to its factory default settings

using the console application, enter the factorydefaults command,

or enter the factorydefaults keepipaddrs command to reset the

Segment Controller but keep its basic IPv4 and IPv6 IP addresses.

For more information about using the Segment Controller console

application, see Appendix B of the i.LON SmartServer User’s Guide.

3. Copy the /config/network/<Network>/<Channel>/<Segment

Controller App Device> folder to the

/config/network/<Network>/<Channel> folder on the flash disk of the

target Segment Controller.

4. Reboot the target Segment Controller using the Segment Controller Web

pages or the Segment Controller console application:

To reboot your Segment Controller using the Segment Controller Web

pages, right-click the local Segment Controller, select Setup, and

select Reboot from the shortcut menu. The Reboot dialog opens.

Click Reboot to start the reboot.

To reboot your Segment Controller using the Segment Controller

console application, enter the reboot command. For more

information about using the Segment Controller console application,

see Appendix B of the i.LON SmartServer User’s Guide.

5. You can open the Web interface of the target Segment Controller and

expand the Segment Controller’s App device in the navigation pane on

the left side. Observe that the functional blocks and data points in the

Segment Controller App device match those of the source. You can click

of the Scheduler functional blocks under the Segment Controller App

device and observe that it has the same configuration as the source.

6. Repeat steps 2–5 to copy the Segment Controller App device

configuration to additional target Segment Controllers.