Echelon Lumewave CRD 3000 Street Light Bridge User Manual

Page 91

Advertising
background image

Street Light Bridge Integrator’s Guide

81

6. Configure the following time (SNTP) server properties:

Time Server Port

The port used by the Segment Controller to receive time data.

The default value is 123, and it cannot be changed. Contact

your IT department to make sure that your firewall is

configured to allow you to access the time server on this port.

Time

Synchronization

Mode

Select the frequency in which the Segment Controller is

synchronized to the SNTP server:

Automatic. The Segment Controller is synchronized every

1 to 15 minutes and remains within 100 ms of the SNTP

server. This is the default, and it can be used for both LAN

and dial-out (modem and GPRS) connections.

Sync when Dial-Up is active. The Segment Controller

clock is synchronized when a dial-out connection is

established. This option can only be used for dial-out

connections (modem and GPRS).

Fixed Interval. The frequency in which the Segment

Controller is synchronized is based on the value in the

Synchronization Interval property. This option can only

be used for Ethernet connections.

Disabled. The Segment Controller is not synchronized with

the SNTP server.

Time

Synchronization

Interval

Set how often the Segment Controller clock is synchronized with

the SNTP server. This option is only available if Fixed

Interval is the selected synchronization method. The default

synchronization interval is 12 hours.

Use As

Select whether this time server is the Default or the Backup

time server. If this is the first time service created on the

Segment Controller, this option is set to Default. If another

time service is currently designated as the default and you

select Default, the default designation will be removed from the

other time server when you click Submit.

Advertising