Echelon Lumewave CRD 3000 Street Light Bridge User Manual

Page 93

Advertising
background image

Street Light Bridge Integrator’s Guide

83

1. Open the Real-Time Clock application on the Segment Controller:

Expand the Net network icon, expand the LON channel, expand the

iLON App (Internal) device, and then click the Real-Time Clock

functional block.

If the Real-Time Clock functional block does not appear in the tree

view, right-click iLON App (Internal) and select Add Functional

Block to open the Add Functional Block dialog. From the dialog, expand

the Static tree and select Real-Time Clock from the tree. Click OK to

add the functional block and close the dialog.

2. The Real Time Clock Configure Web page opens.

3. Configure the following properties for the real-time clock and

astronomical position sensor on the Segment Controller:

In the Latitude property, enter the north-south location of the

Segment Controller relative to the equator. Select the first radio

button to enter the latitude in sexagesimal notation (degrees,

minutes, and seconds); select the second radio button to enter the

latitude as a decimal fraction. If the Segment Controller is located

south of the equator, enter a negative value between 0 and –90. If it

is located north of the equator, enter a positive value between 0 and

90.

In the Longitude property, enter the east-west location of the

Segment Controller relative to the Prime Meridian. Select the first

radio button to enter the longitude in sexagesimal notation (degrees,

minutes, and seconds); select the second radio button to enter the

longitude as a decimal fraction. If the Segment Controller is located

west of the Prime Meridian, enter a negative value between 0 and

–180. If it is located is located east of the Prime Meridian, enter a

positive value between 0 and 180.