Street Light Bridge Integrator’s Guide

85

Controller tree below the iLON App (Internal) device. You can then click the

functional block and begin configuring the Event Scheduler application.
To create a Scheduler functional block and open the application, perform the

following steps:

1. Expand the Net network icon in the Segment Controller tree, and expand

the LON channel to show the iLON App (Internal) device.

2. Right-click the iLON App (Internal) device, and select Add

Functional Block from the shortcut menu.

3. The Add Functional Block dialog opens.

4. Select the Scheduler functional block from the Static or Dynamic

L

ON

M

ARK

folder. The folder available in the dialog depends on whether

the Segment Controller is using the static v12 external interface (XIF)

file or the dynamic v40 XIF file.

If the Segment Controller is using the static v12 XIF file (the

default), expand the Static icon, select the Scheduler functiona1

block, optionally enter a different name than the default

programmatic functional block name, and then click OK.