Street Light Bridge Integrator’s Guide

19

Note that the Segment Controller does not share a power line connection with the

luminaires on the other side of the RF bridge; the CRD 3000 Street Light Bridge

modules forward all communications between the two network segments.

Figure 5. Basic Street Light Bridge Installation (Typical US Installation)

Figure 6. Basic Street Light Bridge Installation (Typical European Installation)

Extending a Basic Installation

A single CRD 3000 Street Light Bridge module can communicate with more than

one companion CRD 3000 Street Light Bridge module to define a more complex

configuration. Figure 7 on page 20 shows an extension to the configuration

shown in Figure 5 (a European installation is not shown, but can be extended in

the same way). A single CRD 3000 Street Light Bridge module communicates

with three CRD 3000 Street Light Bridge modules to further extend the range of

the Segment Controller and provide communications to a greater number of

luminaires.
Communications between the Segment Controller and the network segments in

the foreground (the bottom of Figure 7) connect to the Segment Controller’s

network segment through an RF hop.