Street Light Bridge Integrator’s Guide

45

Street Light Bridge module is powered on; any time spent powered off is not

included in this timeout value.
Because the Street Light Bridge application writes the remaining error

simulation time to onboard flash memory once every 30 minutes, completion of

error simulation might be delayed by up to 30 minutes if the CRD 3000 Street

Light Bridge module is powered off or reset during the simulation.
Updating the nviErrRate data point has the following effect:

If error simulation is active, the error simulation expiration timer is

restarted with the current nciErrTimeout value. Note that setting the

nviErrRate data point to zero still causes the error simulation

expiration timer to restart, even though no errors are simulated.

If error simulation is not active, the value is stored but has no other

immediate effect.

Updating the nviErrMode data point has the following effect:

If error simulation is active, and if nviErrMode is not all zeroes, the

error simulation expiration timer is restarted with the current

nciErrTimeout value.

Setting nviErrMode to all zeroes ends error simulation mode, regardless

of how much time remains.

Updating the nciErrTimeout data point has the following effect:

If error simulation mode is active, error simulation mode is restarted

with the new timeout value, regardless of how much time has already

passed or how much time would be left in the previous simulation.

If error simulation mode is not active, the value is stored but has no other

immediate effect.

Note that a value of zero (0) is not valid for the nciErrTimeout data point; the

Street Light Bridge application rounds a zero value up to 1 (one) to ensure that

error simulation mode can eventually end.

Error Codes

The Segment Controller displays the last error code on the Web page for the CRD

3000 Street Light Bridge module. You can also use network management tools to

send a query status message to the CRD 3000 Street Light Bridge module to

retrieve the error log. See the Neuron Tools Errors Guide (078-0402-01B) for a

listing of Neuron firmware error codes. The Street Light Bridge firmware can

also post the errors listed in Table 1 on page 46.