Street Light Bridge Integrator’s Guide

49

The location of the device (select External)

The XIF file for the device (for example, “slb-normal”)

3. Click OK to add the device. It is added to the tree of its parent channel.
4. Click Submit on the main Segment Controller page to accept the change

to the network.

5. Repeat steps 1–4 for each device on the network to be installed.

Entering Device Locations and Neuron IDs

Use the Segment Controller Web pages to enter the locations and Neuron IDs of

the devices being installed:

1. Select the device from the LON device tree to display the device

properties page.

2. From the Setup tab, specify the 12-digit hex string comprising the

device’s Neuron ID in the Neuron ID field.

3. You should also enter a description of the device location such as a light

pole number or GPS coordinates that can be associated with the device in

the Geographical Position field.

4. Click Submit. The Segment Controller discovers the repeating path for

the device and commissions it.

5. Repeat steps 1–5 for each device on the network to be installed.

Selecting Devices

After entering the locations and Neuron IDs of the devices to be installed, you

select those devices on the tree:

1. Select one or more devices from the tree to be installed.

Advertising