Example installations, Basic installation, Figure 4 – Echelon Lumewave CRD 3000 Street Light Bridge User Manual

Page 28

Advertising
background image

18

Installation for the Street Lighting Solution

t

[ms]

Excellent

Good

Fair

Poor

Naught

0

150

500

850

1000

One period (1000ms)

Figure 4. RF Signal Quality as Represented by the RF Signal LED

The flashing pattern of the RF signal LED allows the installer to confirm good

RF communications with nearby CRD 3000 Street Light Bridge modules without

having to return to the Segment Controller. Echelon does not recommend using

a link that indicates poor or no margin; such a link is likely to have poor

reliability.
However, the RF communications indicated by the LED could possibly be with an

unrelated street lighting network that uses a different Segment Controller than

the network into which you installed the CRD 3000 Street Light Bridge module.

In addition, the quality of the RF communications link has some dependency on

ambient temperature conditions, so you should verify RF communications at

extreme temperatures as well as at nominal temperatures.
By default, both LEDs turn off after one hour. You can modify this timeout value

by updating the nciLedTimeout data point. Setting this data point to zero

disables LED shutoff (that is, the LEDs remain on or flashing indefinitely). See

Appendix A, Interoperable Interface for the Street Light Bridge, on page 103, for

more information about this and other data points that comprise the Street Light

Bridge interoperable interface.

Example Installations

You can install CRD 3000 Street Light Bridge modules in almost any

configuration to provide power line and radio frequency communications for

street lights within a street lighting solution.
In the figures, the street lights in the figures are shown in straight lines, but they

could be in any physical configuration. Also, the service distribution

transformers are shown installed on utility poles, but the transformers could be

pad mounted.

Basic Installation

Figure 5 and Figure 6 on page 19 shows a basic installation with a Segment

Controller and two CRD 3000 Street Light Bridge modules. The Segment

Controller uses the power line communications channel for the nearest set of

luminaires, and two CRD 3000 Street Light Bridge modules provide the

communications bridge between the two service distribution transformers.

Advertising