Managing a Street Lighting Network

Available Proxies The approximate number of repeating devices that can directly

communicate with the device, including the current proxy. The

signal strength at the repeating device and the number of hops

required to reach it determine whether a repeating device can

serve as a proxy for a given device.

Failure History

(24h).

Lists the 45-minutes intervals within the current 24-hour period

in which a device failure (if any) was reported.

Note: The data displayed in the Web page are cached values (not real-

time measurements). You can click Refresh to get the latest cached

values.
Repeating devices marked offline (red) in the tree view might not be

marked as such in the Powerline Repeating Analysis Web page; likewise,

devices marked offline (red) in the Powerline Repeating Analysis Web

page might not be marked as such in the tree view. Furthermore, there

could be a significant delay for a device in this Web page to show the

offline state if you have not configured the Use Offline Delay property

in the Setup – LON Channel Driver Web page. See Configuring the

LonWorks Channel for Power Line Repeating on page 25 for more

information about setting this property.

5. You can display the following advanced diagnostic statistics for a given

target device by clicking the Display Advanced Information checkbox:

Commission

Status

Indicates whether the device has been commissioned. The

values that can appear in this field and their colors depend on

whether the device has successfully been installed (black), is

being installed (orange), or has an error (red).