Placing the segment controller in standalone mode, Placing a network in standalone mode, Network limitations in standalone mode – Echelon Lumewave CRD 3000 Street Light Bridge User Manual

Page 34

Advertising
background image

24

Setting Up the Segment Controller

Placing the Segment Controller in Standalone

Mode

A street lighting network is a power line repeating network, which requires that

the Segment Controller operate in standalone mode with power line repeating

enabled. Standalone mode allows the Segment Controller to operate as the

exclusive network manager of the system, and to establish and maintain the

appropriate repeating chains. A repeating chain is the path that a message must

travel on the PL-20 or RF channel from the Segment Controller to one or more

repeating devices (luminaires or CRD 3000 Street Light Bridge modules) before

reaching the target device (a luminaire or a CRD 3000 Street Light Bridge

module).
In standalone mode, the Segment Controller controls the network management

commands sent to the devices attached to its channel. In this mode, the Segment

Controller can directly download the application image file to the devices and

commission, set the application state (online/offline), wink, test, and reset the

devices attached to its channel.

Placing a Network in Standalone Mode

To set a network to standalone mode using the Segment Controller Web pages,

perform the following steps:

1. Open the Segment Controller Web pages, as described in Chapter 3 of the

i.LON SmartServer User’s Guide.

2. Click the Net network to display the Lon Network Property page.
3. From the Setup tab, select Standalone.

4. Click Submit. A dialog appears informing you that the Segment

Controller is switching to standalone mode.

It could take several minutes for the Segment Controller to switch to standalone

mode. After the Segment Controller has switched to standalone mode, the dialog

closes and you can continue preparing your Segment Controller for the network

installation.

Network Limitations in Standalone Mode

Managing a power line repeating network in standalone mode has the following

restrictions:

Network is limited to a maximum of approximately 200 devices

(luminaires and CRD 3000 Street Light Bridge modules).

Advertising