Ground stacks, V8/v12 ground stack, Þ chapter 3.4 – d&b V-Series User Manual

Page 35

Advertising
background image

3.4. Ground stacks

WARNING!
Potential risk of personal injury and/or

damage to material!

Always secure ground stacked setups against movement and

possible tipping over.
Observe the maximum number of cabinets permitted. This is

particularly important when setting up mixed ground stacks.

3.4.1. V8/V12 ground stack
Limitations
A maximum of 8 x TOP cabinets with the V Flying frame serving as

ground support are allowed to be set up as ground stack.

Preparations
In this type of setup the V Flying frame is used as ground support.

For this purpose, the Splay link of the frame must be removed and

stored in a safe place.

The Locking pin of the Cable pick will be used to fix the vertical

aiming of the first TOP cabinet on the Flying frame at a later stage.

For this reason, the Cable pick assembly (O-ring) must be attached

to hole 35 of the Frame's hole grid.

Proceed as follows:

1. Prepare the Flying frame
To attach the TOP cabinets to the Flying frame, the two additional

Front links of the frame are required.

1. Remove the additional Front links together with their Locking

pins from the park position on the frame.

2. Attach the additional Front links at the top of the front tracks of

the frame and fix them using one Locking pin.

Þ Observe the direction of attachment as shown in the

graphic opposite.

Splay link removed and Cable pick attached to hole 35.

d&b V-Series Rigging manual (1.9 EN)

35

Advertising
This manual is related to the following products: