5.4 Synchronizing more than 2 Nugget Units

If you have more than 2 Nugget units to synchronize:

•

Designate one unit as Master and the rest as slaves

•

Connect the LTC OUT of the Master to an analog video distribution amplifier (an analog
audio DA is more suitable, but a video DA is easier to connect because it has BNC
connectors)

•

Follow the same synchronization instructions in the previous 2 paragraphs. (change this)

NOTE: We strongly recommend using a DA to distribute the LTC from the Master to multiple
Slave units as opposed to daisy chaining LTC between units, but if a DA is not available, daisy
chaining will be acceptable until a DA is added to the system.

5.5 LTC IN Latency

If you want the Nugget to chase 1 or 2 frames ahead of the incoming LTC, you can set the LTC
IN Latency to 1 or 2. Values up to 5 are allowed, default value is 0.