1 parameter channel, 1 parameter id (pke), 1 interpretation of the response ids – BECKHOFF AX2000 PROFIBUS DP communication profile User Manual

Page 16: Parameter channel, Parameter id, Response ids, Parameter id (pke), Interpretation of the response ids, 1 parameter channel 3.1.1 parameter id (pke), Beckhoff

Advertising
background image

3.1

Parameter channel

3.1.1

Parameter ID (PKE)

Marked lines in the table are valid for AX2000/2500

Master —> Slave

Slave —> Master

Task ID

Function

Response ID positive

Response ID negative

0

no task

0

0

1

request parameter value

1,2

7

2

alter parameter value [W]

1

7/8

3

alter parameter value [DW]

2

7/8

4

request description element

3

7

5

alter description element

3

7/8

6

request parameter value [A]

4,5

7

7

alter parameter value [A/W]

4

7/8

8

alter parameter value

5

7/8

9

request number of array elements

6

7

10 - 15

reserved

3.1.1.1

Interpretation of the response IDs

Marked lines in the table are valid for AX2000/2500

Response ID

Interpretation

0

no task

1

transmit parameter value

2

transmit parameter value

3

transmit description element

4

transmit parameter value

5

transmit parameter value

6

transmit number of array elements

7

task not possible (with error no.)

8

no operating authority for PKW interface

9

spontaneous message [W]

10

spontaneous message [DW]

11

spontaneous message [A/W]

12

spontaneous message [A/DW]

Abbreviatoins in the tables:

A:

Array

W:

Word

DW:

Double-word

16

PROFIBUS for AX2000/2500

Profile of AX2000/2500

12/05

BECKHOFF