4.2.6

Setup mode: position

4.2.6.1

PNU 1773: homing type

This parameter can be used to determine which type of homing run should be applied. The
assignment can be seen in the following table:

PWE

Type of homing run

0

Reference point at the present position

1

Initiator with resolver zero mark

2

Hardware limit-switch resolver zero mark

3

Initiator without resolver zero mark

4

Hardware limit-switch without resolver zero mark

5

Zero mark / feedback unit

6

Reference point at the actual position

7

Hardware limit-switch with resolver zero mark

8

Absolute SSI-position

9

Move to Mechanical Stop

4.2.6.2

PNU 1644: homing direction

This parameter can be used to determine the direction of motion for homing runs. If set equal 0,
then the direction of motion is negative; for a value 1 it is positive, and for a 2 it depends on the dis-
tance to the reference point in the direction in which the homing run started.

4.2.7

Actual values

4.2.7.1

PNU 1401: speed

The parameter value is the actual speed of the motor in increments / 250 µsec, which are the
amplifier’s internal units.

4.2.7.2

PNU 1402: incremental position, actual value

The parameter value is the actual position value in increments.

4.2.7.3

PNU 1800: actual position value in SI (User) units

The parameter value is the actual SI (user unit) position value.

4.2.7.4

PNU 1414: actual position, 32 bit floating decimal point format

With this object the actual position (see ASCII-command PFB) can be read in a 32 Bit Floating deci-
mal point format (IEEE).
Right of decimal point positions will be truncated. This object is, aside from the data format, identi-
cal to PNU1800.
Use:
PLC Controls that support only 16 Bit integer and 32 Bit floating decimal point.

PROFIBUS for AX2000/2500

29