2 digital speed (operating mode 1), 3 analog speed (operating mode -1), Digital speed (operating mode 1) – BECKHOFF AX2000 PROFIBUS DP communication profile User Manual

Page 39: Analog speed (operating mode -1), Process data channel

Advertising
background image

5.2.2

Digital speed (operating mode 1)

Direction

PZD 1

PZD 2

PZD 3

PZD 4

PZD 5

PZD 6

Controller to Amplifier

STW

n

cmd

-

-

-

Amplifier to Controller

ZSW

n

act

-

incremental actual position

32-bit

manuf.-specific

status

Alternative assignment of the process data sections with STW Bit 14=1:

Direction

PZD 1

PZD 2

PZD 3

PZD 4

PZD 5

PZD 6

Controller to Amplifier

STW

n

cmd

(32-bit)

-

-

Amplifier to Controller

ZSW

n

act

(32-bit)

incremental actual position

32-bit

manuf.-specific

status

Alternative assignment of the process data sections with STW Bit 15=1:

Direction

PZD 1

PZD 2

PZD 3

PZD 4

PZD 5

PZD 6

Controller to Amplifier

STW

n

cmd

-

-

-

Amplifier to Controller

ZSW

n

act

-

position (20 bits/turn and 16

turns)

manuf.-specific

status

Actual speed n

act

(16-bit)

The representation of the 16-bit actual speed value is normalized to the parameter for the

overspeed VOSPD

n

n

VOSPD

act

act

16

15

2

=

´

Actual position (32-bit)

The range for the incremental position covers values from -2

31

to (2

31

-1).

Here one turn corresponds to 2

PRBASE

increments. Reporting the information in User

Units (SI) is not supported.

Manufacturer-specific status

In the process data (PZD5), the upper 16 bits of the manufacturer-specific status register
(PNU 1002) are made available. The numbering starts again from 0.
The significance of the status register bits can be seen in the table in Chapter 4.2.3.3.

Speed setpoint n

cmd

(16-bit)

The 16-bit speed setpoint is normalized to the parameter for the
overspeed VOSPD.

n

n

VOSPD

cmd

cmd

16

15

2

=

´

Position

The actual position value is an incremental value with a resolution of 24 bits.
Her one turn corresponds to 2

PRBASE

increments.

So 2

24 - PRBASE

turns can be represented.

Speed values n

act

(32-bit)

The digital speed values are converted according to the formula.

(

)

n

in rpm

n

60 4000

32 2

cmd/ act

cmd/ act, dig.

PRBASE

=

´

´

´

with 2

PRBASE

= Increments per Motor turn, 60s/min,

4000 = Number of position controller cycles / sec.

5.2.3

Analog speed (operating mode -1)

In this operating mode the control word (STW) can only be used to enable and disable the amplifier.

Direction

PZD 1

PZD 2

PZD 3

PZD 4

PZD 5

PZD 6

Controller to Amplifier

STW

-

-

-

-

-

Amplifier to Controller

ZSW

n

act

-

incremental actual position

32-bit

manuf.-specific

status

PROFIBUS for AX2000/2500

39

BECKHOFF

12/05

Process data channel

Advertising