Manufacturer specific object channel (from PNU 1600)

With PNUs>1600 you can programm each ASCII-parameter/command of the AX2000/2500. The
PNU can be calculated by the object number with a specific offset (ASCII command reference list:
DPR).
All PNUs described in this manual can be reached with index=1. In the ASCII reference list you find
for every parameter the PNU and the referring index. More functions of the object channel can be
used with the indices listed below.

The offset and the indices that must be used depend on the object number:

Objekt number

Offset

PNUs

Index

0 ...447

1600

1600 ...2047

00h ...08h (1 ... 8dez)

448 ...847

1200

1648 ...2047

10h ...18h (16 ... 24dez)

848 ...1047

800

1648 ...2047

20h ...28h (32 ...40dez)

Index

0/10h/ 20h depending on the object no. (see above)

short description

Number of entries

Unit

Access

Data type

UNSIGNED8

Value range

0 ... 2

8

-1

EEPROM

Index

1/11h/ 21h depending on the object no. (see above)

short description

read/write a parameter

Unit

see corresponding ASCII-command

Access

see corresponding ASCII-command

Data type

see corresponding ASCII-command

Value range

see corresponding ASCII-command

Default value

EEPROM

see corresponding ASCII-command

Index

2/12h/ 22h depending on the object no. (see above)

short description

read lower limit

Unit

see corresponding ASCII-command

Access

Read only

Data type

see corresponding ASCII-command

Value range

see corresponding ASCII-command

Default value

EEPROM

Index

3/13h/ 23h depending on the object no. (see above)

short description

read upper limit

Unit

see corresponding ASCII-command

Access

Read only

Data type

see corresponding ASCII-command

Value range

see corresponding ASCII-command

Default value

EEPROM

Index

4/14h/ 24h depending on the object no. (see above)

short description

read default value

Unit

see corresponding ASCII-command

Access

Read only

Data type

see corresponding ASCII-command

Value range

see corresponding ASCII-command

Default value

EEPROM

PROFIBUS for AX2000/2500

31

BECKHOFF

12/05

Using the parameter channel (PKW)