Using the parameter channel (pkw) – BECKHOFF AX2000 PROFIBUS DP communication profile User Manual

Page 21

Advertising
background image

PNU

Data type

Access Description

ASCII com-

mand

PNU (old)

Position set-up mode

1773

UINT32

r/w

Homing type

NREF

1350

1644

UINT32

r/w

Homing direction

DREF

1351

1602

UINT32

r/w

Acceleration ramp (jogging/homing)

ACCR

1352

1636

UINT32

r/w

Braking ramp

DECR

1353

1831

UINT32

r/w

Reference offset

ROFFS

1354

1896

UINT32

ro

Homing run velocity

VREF

1355

1889

UINT32

ro

Jogging velocity

VJOG

1356

Actual values

1400

INTEGER32

ro

Actual position 20 bits/turn

PRD

1400

1401

INTEGER32

ro

Speed

1401

1402

INTEGER32

ro

Incremental position, actual value

1402

1800

INTEGER32

ro

SI-position, actual value

PFB

1403

1815

INTEGER32

ro

SI-velocity, actual value

PV

1404

1797

INTEGER32

ro

SI following error

PE

1405

1688

INTEGER32

ro

RMS current

I

1406

1880

INTEGER32

ro

SI-speed, actual value

V

1407

1873

INTEGER32

ro

Heatsink temperature

TEMPH

1408

1872

INTEGER32

ro

Internal temperature

TEMPE

1409

1882

INTEGER32

ro

DC-bus (DC-link) voltage

VBUS

1410

1792

INTEGER32

ro

Regen power

PBAL

1411

1689

INTEGER32

ro

I2t - loading

I2T

1412

1876

INTEGER32

ro

Running time

TRUN

1413

1414

special

ro

Position, 32 bit floating decimal point format

1414

1415

special

ro

Velocity, 32 bit floating decimal point format

1415

Digital I/O configuration

1698

UINT32

r/w

Function of digital input 1

IN1MODE

1450

1701

UINT32

r/w

Function of digital input 2

IN2MODE

1451

1704

UINT32

r/w

Function of digital input 3

IN3MODE

1452

1707

UINT32

r/w

Function of digital input 4

IN4MODE

1453

1699

INTEGER32

r/w

Auxiliary variable for digital input 1

IN1TRIG

1454

1702

INTEGER32

r/w

Auxiliary variable for digital input 2

IN2TRIG

1455

1705

INTEGER32

r/w

Auxiliary variable for digital input 3

IN3TRIG

1456

1708

INTEGER32

r/w

Auxiliary variable for digital input 4

IN4TRIG

1457

1775

INTEGER32

r/w

Function of digital input 1

O1MODE

1458

1778

INTEGER32

r/w

Function of digital input 2

O2MODE

1459

1776

UINT32

r/w

Auxiliary variable for digital output 1

O1TRIG

1460

1779

UINT32

r/w

Auxiliary variable for digital output 2

O2TRIG

1461

1852

UINT32

r/w

State of 4 digital inputs, Enable,
2 digital outputs

STATIO

1462

Analog configuration

1607

UINT32

r/w

Configuration of the analog input functions

ANCNFG

1500

1613

UINT32

r/w

Configuration monitor function analog output 1

ANOUT1

1501

1611

UINT32

r/w

Offset voltage for analog input 1

ANOFF1

1502

1617

UINT32

r/w

Filter time constant for analog input 1

AVZ1

1503

1897

UINT32

r/w

Scaling factor for velocity, analog input 1

VSCALE1

1504

1713

UINT32

r/w

Scaling factor for current, analog input 1

ISCALE1

1505

1614

UINT32

r/w

Configuration monitor function analog output 2

ANOUT2

1506

1612

UINT32

r/w

Offset voltage for analog input 2

ANOFF2

1507

1898

UINT32

r/w

Scaling factor for velocity, analog input 2

VSCALE2

1508

1714

UINT32

r/w

Scaling factor for current, analog input 2

ISCALE2

1509

Motor parameters

1735

UINT32

r/w

Brake configuration

MBRAKE

1550

1753

UINT32

r/w

Motor number from motor database

MNUMBER

1551

Manufacturer specific object channel

³1600

Þ p. 31 and description of the ASCII-commands on the CDROM or in the online help.

³1600

Abbreviations in the “Access” column

Abbrev.

Description

wo

“write only” access

ro

“read only” access

r/w

read and write access

PROFIBUS for AX2000/2500

21

BECKHOFF

12/05

Using the parameter channel (PKW)

Advertising