Transitions of the status machine

Transition

Description

0

Event Reset / 24V supply is switched on

Action Initialization started

1

Event Initialization successfully completed, AX2000/2500 switch-on inhibit

Action none

2

Event

Bit 1 (inhibit voltage) and Bit 2 (fast stop) are set in the control word
(command: shutdown). DC bus link voltage is present.

Action none

3

Event Bit 0 (switch-on) is also set (command: switch-on)

Action Output stage is switched on (enabled). Motor has torque.

4

Event Bit 3 (operation enabled) is also set (command: operation enable)

Action Motion functions are enabled, depending on the operating mode that is set.

5

Event Bit 3 is canceled (command: inhibit)

Action

Motion functions are disabled.
Motor is braked, using the relevant ramp (depends on operating mode).

6

Event Bit 0 is canceled (ready for switch-on).

Action Output stage is switched off (disabled). Motor has no torque.

7

Event Bit 1 or Bit 2 is canceled.

Action (Command: “Fast stop” or “Inhibit voltage”)

8

Event Bit 0 is canceled (operation enabled -> ready for switch-on)

Action Output stage is switched off (disabled) - motor has no torque.

9

Event Bit 1 is canceled (operation enabled -> switch-on inhibited)

Action Output stage is switched off (disabled) - motor has no torque.

10

Event Bit 1 or 2 are canceled (ready for operation -> switch-on inhibited)

Action Output stage is switched off (disabled) - motor has no torque.

11

Event Bit 4 is canceled (operation enabled -> fast stop)

Action

Drive is stopped, using the emergency ramp. The output stage remains enabled. Setpoints are
canceled (e.g motion block number, digital setpoint).

12

Event Bit 1 is canceled (fast stop -> switch-on inhibited)

Action Output stage is switched off (disabled) - motor has no torque.

13

Event Error response active

Action Output stage is switched off (disabled) - motor has no torque.

14

Event Error

Action none

15

Event Bit 7 is set (error -> switch-on inhibited)

Action Acknowledge error (depending on error – with/without reset)

16

Event Bit 4 is set (fast stop -> operation enabled)

Action Motion function is enabled again.

17

Event Bit 2 is canceled

Action Switch-on inhibited, output stage disabled

The state transitions are affected by internal events (e.g. switching off the DC-link voltage) and by