Control word (STW)

With the aid of the control word, you can switch from one amplifier state to another. In the diagram
for the state machine you can see which instrument states can be reached by which transitions. The
momentary amplifier state can be taken from the status word.
Several states may be passed through during one telegram cycle, e.g.

Ready for switch on

® Ready for operation ® Operation enabled.

The bits in the control word can be (operating-) mode-dependent or mode-independent.
The following table describes the bit assignment in the control word.

Bit

Name

Commentary

0

Switch on

1

Inhibit voltage

2

Fast stop, switch-on inhibited

1 -> 0 drive decelerates using emergency ramp, axis is disabled

(See also ASCII-commands STOPMODE and DECDIS)

3

Operation enabled

4

Fast stop (inhibit rfg)

1 -> 0 drive decelerates using emergency ramp,
the amplifier remains enabled

5

Pause (stop rfg)

Operating mode dependent, 1 -> 0 stops motion

6

Setpoint enable

Operating mode dependent (see table below)

7

Reset Fault

only effective with errors

8

Jogging (on/off)

Operating mode dependent (see table below)

9

reserved

10

PZD (enable/inhibit)

11

Start homing run (edge)

Operating mode dependent (see table below)

12

Manufacturer-specific

reset the position

13

Manufacturer-specific

acknowledge warnings

14

Manufacturer-specific

only position opmode: Bit14 = 1: PZD section is interpreted as direct
motion block (velocity 32-bit, position 32-bit, motion block type 16-bit
Bit14 = 0: PZD section (HSW) is interpreted as motion block number

15

Manufacturer-specific

Operating mode dependent, digital speed

Depending on the bit combination in the control word, a corresponding control command is defined.
The following table shows the bit combinations and also determines the priorities of the individual
bits, in case several bits are altered in one telegram cycle.

Command

Bit 13

Bit 7

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Transitions

Shutdown

X

X

X

X

1

1

0

2, 6, 8

Switch-on

X

X

X

X

1

1

1

3

Inhibit voltage

X

X

X

X

X

0

X

7, 9, 10, 12

Fast stop (amplifier is disabled)

X

X

X

X

0

1

X

7, 10,11->12

Fast stop (amplifier remains enabled)

X

X

0

1

1

1

1

11

Inhibit operation

X

X

X

0

1

1

1

5

Enable operation

X

X

1

1

1

1

1

4, 16

Reset error

X

1

X

X

X

X

X

15

Acknowledge warnings

1

X

X

X

X

X

X

-

Bits labeled with X are irrelevant.

Opmode-dependent bits in the control word:

Mode

Bit 5

Bit 6

Bit 8

Bit 11

Position

Motion block:
The parameter that is set in the mo-
tion block is used.
Setup operation:
The parameter that is set as a ramp
for homing and jogging is used

Start a motion task with every
transition edge
(toggle bit).

Start
jogging

Start homing

Digital speed

Drive brakes, using the preset
speed ramp.

Setpoint enable, start movement reserved reserved

Digital current

reserved

Setpoint enable, start movement reserved reserved

Analog speed

reserved

reserved

reserved reserved

Analog current reserved

reserved

reserved reserved

Trajectory

reserved

reserved

reserved reserved

Priority of the Bits 6, 8, 11 in position-control mode: 6 (high), 11, 8 (low).