background image

3.1.1.2

Response ID 7: Profile specific error numbers

Error no.

Description

0

illegal PNU

1

parameter value cannot be changed

2

Lower or upper limit violated

3

Erroneous sub-index

4

no array

5

Incorrect data type

6

setting not allowed (can only be reset)

7

Descriptive element cannot be changed

8

PPO-write, requested in IR, not available

9

descriptive data not available

10

access group incorrect

11

No parameter change rights

12

Password incorrect

13

Text cannot be read in cyclic data transmission

14

Name cannot be read in cyclic data transmission

15

text array not available

16

PPO-write missing

17

task cannot be executed due to operating status

18

other error

19-100

reserved

101

faulty task ID

102

software error (command table)

103

only possible in disabled state

104

only possible in enabled state

105

BCC-error in the EEPROM data

106

only possible after task is stopped

107

wrong value [16,20]

108

wrong parameter (OCOPY x [- y] z)

109

wrong motion block no. (0,1..180,192..255)

110

wrong parameter (PTEACH x [y])

111

EEPROM write error

112

wrong value

113

BCC-error in motion block

114

Object is read only or write only

115

Incompatible object (SDO channel only)

>115

reserve

3.1.2

Index IND

An Index (IND) unequal to 0 is used for reading and writing amplifier parameters
with PNUs > 1600. See page 31
for further description.

PROFIBUS for AX2000/2500

17

BECKHOFF

12/05

Profile of AX2000/2500