Status word (ZSW)

With the help of the status word, the amplifier state can be represented and a transmitted control
word can be verified.

If the amplifier does not react to changes of the control word (STW) as expected, the marginal con-
ditions like (enable of the output stage – hardware + software, application of the DC bus link vol-
tage) must be checked.

The bits in the status word can be mode-dependent or mode-independent.
The following table describes the bit assignment in the status word.

Bit

Name

Commentary

0

Ready for switch-on

---

1

Switched on

---

2

Operation enabled

---

3

Error

see ASCII command ERRCODE

4

Voltage inhibited

---

5

Fast stop

---

6

Switch-on inhibit

---

7

Warning

see ASCII command STATCODE

8

Setpoint / actual value monitoring

only in position-control opmode: following error indicator

9

Remote

not supported, fixed to 1

10

Setpoint reached

only in position mode: In Position

11

Limit active

not supported at present

12

Depends on mode

used in ASCII-mode

13

Depends on mode

used in ASCII-mode

14

Manufacturer-specific

used in ASCII-mode

15

Manufacturer-specific

reserved

States of the status machine:

State

Bit 6

Bit 5

Bit 4

Bit 3

Bit 2

Bit 1

Bit 0

Not ready for
switch-on

0

X

X

0

0

0

0

Switch-on inhibit

1

X

X

0

0

0

0

Ready for switch-on

0

1

X

0

0

0

1

Ready for operation

0

1

X

0

0

1

1

Operation enabled

0

1

X

0

1

1

1

Error

0

X

X

1

X

X

X

Error response

0

X

X

1

0

0

0

Fast stop active

0

0

X

0

1

1

1

5.2

Operating modes

The selection of a new operating mode is described in detail on p. 23. This procedure must be follo-
wed for proper amplifier operation.

WARNING
Appropriate precautionary measures against damage caused by faulty presentation of data
formats or normalization of the setpoints must be taken by the user.

The possible operating modes are described below. PROFIBUS operating modes with a positive
number (1,2) are defined in the drive profile. Operating modes with a negative number (-1,-2...) are
labeled in the drive profile as being manufacturer-specific modes.

PROFIBUS for AX2000/2500

37

BECKHOFF

12/05