3.3

Program stop

For an immediate stop in case of operating errors, needle breakage
etc. the safety system of the 1281/5 provides the following measures:
–

Press program stop switch 2 at the control panel.
The running operations are stopped immediately.

–

Turn main switch 1 counter-clockwise.
The sewing unit drops out immediately;
all movements of the sewing unit stop immediately.

3.4

Restart after program stop

Caution: Risk of injury!

Switch the main switch off.
Clear the fault only with the sewing unit switched off.

Only restart the sewing unit after the fault has been cleared.

–

Switch on main switch 1 (turn in clockwise direction).

–

Unlock the program stop switch.
The control loads the machine program.
The basic display appears in the display of the control panel.
The sewing unit is ready for operation again.