6.4.1

Altering seam-specific parameters

Needle feed (with cylinder)

Via this parameter the needle feed is set.

Parameter 01:

Line 1
Number of stitches until the needle feed engages

Setting range:

0 - 2000

Parameter 02:

Fullness line 1 ON/ OFF

Setting range:

0 / 1

Parameter 03:

Line 2
Number of stitches how long the needle feed is
engaged

Setting range:

0 - 2000

Parameter 04:

Fullness line 2 ON/ OFF

Setting range:

0/1

Parameter 05:

Line 3
Number of stitches how long the needle feed is
engaged

Setting range:

0 - 2000

Parameter 06:

Fullness line 3 ON/ OFF

Setting range:

0/1

Needle feed (with step motor)

Via this parameter the needle feed with step motor drive is set.

Parameter 01:

Line 1
Number of stitches

Setting range:

0 - 2000

Parameter 02:

Fullness in line 1

Setting range:

0 - 2000

Parameter 03:

Line 2
Number of stitches

Setting range:

0 - 2000

Parameter 04:

Fullness in line 2

Setting range:

0 - 2000

Parameter 05:

Line 3
Number of stitches

Setting range:

0 - 2000

Parameter 06:

Fullness in line 3

Setting range:

0 - 2000

27