6.4.2

Altering global parameters

Parameter 29:

Needle feed
Maximum run

Input:

0 …120

Parameter 38:

Start delay light barrier

Input:

0 …2000

Parameter 39:

Differential feed
Maximum run

Input:

0 …120

Parameter 40:

Basic value needle feed

Input:

0 …120

Parameter 41:

Basic value needle feed on / off

Input:

0 / 1

Parameter 42:

Basic value differential bottom feed

Input:

0 …120

Parameter 43:

Basic value differential bottom feed on/ off

Input:

0 / 1

Parameter 45:

Number of stitches until the table blowing is
switched on

Input:

0 …400

Parameter 46:

Duration of the stacker impulse

Input:

0 ...2000

Parameter 47:

Time of the stacker movement

Input:

0 …2000

Parameter 48:

Speed limitation

Input:

max. 6500

Parameter 49:

Speed during the warp separation

Input:

500...5000

Parameter 50:

Number of stitches until the thread tension is opened
(seam end)

Input:

0....50

Parameter 52:

Speed ejector roller

Input:

500 … 1200

Parameter 54:

Duration of impulse “mouse back”

Input:

500 … 4000

Parameter 55:

Time until the feeding unit lifts after the ejector roller

Input:

0....2000

Parameter 56:

Seam programming on/ off
On = 1

Determine the seam sequences in the

current program

.

Off = 0

Create the next free program with seams
Input:

0 / 1

Parameter 80:

Reset the daily piece counter.