Altering the machine parameters

Parameter 30:

Set the main speed

Setting range:

0 - 6500

Parameter 31:

Manual sewing on/ off

Setting range:

0 / 1

Parameter 32:

Number of stitches how long the table blowing
remains switched on

Setting range:

0 …400 stitches

Parameter 33:

Number of stitches until the automatic start engages
after the sewing start

Setting range:

0 ...

Parameter 34:

Number of stitches until the contour guide lowers

Setting range:

0 …400 stitches

Parameter 35:

Number of stitches until the contour guide retracts
laterally

Setting range:

0 …400 stitches

Parameter 36:

Number of stitches until the feeding unit lowers

Setting range: 0 ...400

Parameter 37:

Start mode contour modulation
1 = front, left
2 = rear, right
3 = rear, left

Setting range:

Modes 1, 2, 3

Parameter 60:

Soft start speed

Setting range:

500 ...5000

Parameter 61:

Switch the soft start on or off

Setting range:

0 / 1

Parameter 76:

Switch the start on or off via light barrier

Setting range:

0 / 1

Parameter 77:

Switch the autostart on or off

Setting range:

0 / 1

Parameter 78:

Number of stitches until the autostart starts

Setting range:

0 ...400 stitches