Maintenance work

Explanation

Operating

to be done

hours

Machine head

- Remove sewing dust and thread
remainders.
(e.g. with compressed air pistol)

Clean the entire area 1 of the thread guides
under the fabric sliding sheet

8

Suction device

Empty container 2 of the suction device
-

Turn the bottom part of the container to the

left

and remove it

-

Empty the container

-

Screw the bottom part on again in

clockwise direction

8

Pneumatic system
- Check the water level in the
pressure regulator 3

- Clean the filter insert 4

- Make leak test of the system

The water level must not rise up to the filter
insert 4.
-

Let the water run out of the water separator

under pressure after pressing the drain plug 5.

The filter insert 4 separates dirt and condensed
water.
-

Separate the sewing unit from the

compressed air net.
-

Push in drain plug 5.
The pneumatic system of the
sewing unit has to be pressureless.

-

Screw the water separator 6 off

-

Remove filter insert 4.
Wash the dirty filter tray and the filter insert
with benzine (no solvent!)
and blow them clean.

-

Reassemble the water separator
and connect the maintenance unit.

40

500

500

47

1