6.4.4

Creation of seam programs

Note

Before a new seam program can be created or an existing one can be
deleted, the global parameter “56” has to be set to the value “0”.
This avoids that the existing programs are changed inadvertently.

Press key “P”.

Press key “0” (global parameters).

Change over to parameter 56 with key “F1”.

Press key “E”.
The parameter 56 is selected.

Set the parameter value to “0" with key “Minus.

Press key “P”.
The new parameter value is stored.

Press key “P”.
You return to the selection menu.

Creating a seam program

Press key “P”.

Press key “9” (Prg = programs).

Press key “F1” twice.

Select a seam with one of the keys “1” to “9”.

Press key “E”.
The selected seam is taken over.

Select a further seam with one of the keys “1” to “9”.

or

Press key “P”.
The new setting is stored and you return to the selection menu.

Note

After the creation of a new seam program the parameter “56" has to be
reset to the value “1” for safety reasons.