Bottom feed (with cylinder)

Via this parameter the differential feed is set.

Parameter 07:

Line 1
Number of stitches until the differential bottom feed
engages

Setting range:

0 - 2000

Parameter 08:

Fullness line 1 ON/ OFF

Setting range:

0 / 1

Parameter 09:

Line 2
Number of stitches how long the differential bottom
feed is engaged

Setting range:

0 - 2000

Parameter 10:

Fullness line 2 ON/ OFF

Setting range:

0 / 1

Parameter 11:

Line 3
Number of stitches how long the differential bottom
feed is engaged

Setting range:

0 - 2000

Parameter 12:

Fullness line 2 ON/ OFF

Setting range:

0 / 1

Bottom feed (with step motor)

Via this parameter the differential feed with step motor drive is set.

Parameter 07:

Line 1
Number of stitches

Setting range:

0 - 2000

Parameter 08:

Fullness in line 1

Setting range:

0 - 2000

Parameter 09:

Line 2
Number of stitches

Setting range:

0 - 2000

Parameter 10:

Fullness in line 2

Setting range:

0 - 2000

Parameter 11:

Line 3
Number of stitches

Setting range:

0 - 2000

Parameter 12:

Fullness in line 3

Setting range:

0 - 2000