Setting the ejector roller

Via this parameter the ejector roller is set.

Parameter 16:

Number of stitches how long the seam chain
is sucked (seam beginning)

Setting range:

0....120

Parameter 17:

Switch the stacker on or off

Setting range:

0 / 1

Parameter 20:

Number of stitches when the ejector roller lowers

Setting range:

0 …400 stitches

Parameter 21:

Number of stitches how long the ejector roller is
switched on

Setting range:

0 …400 stitches

Parameter 22:

Number of stitches after “light barrier bright”, until
the ejector roller stops

Setting range:

0 …30 stitches

Parameter 23:

Time how long the ejector roller is active

Setting range:

0 …1000

Parameter 47:

Time of the stacker movement

Input:

0 …2000

Parameter 53:

Time when the ejector roller lifts

Setting range:

0 …2000

Setting the puller

Via this parameter the puller is set.

Parameter 26:

Number of stitches when the puller lowers

Setting range:

0 …400 stitches

Parameter 27:

Number of stitches how long the puller remains
lowered

Setting range:

0 …400 stitches

Parameter 51:

Puller speed
lower value = increased puller speed
higher value = lower puller speed

Setting range:

400 … 1000

Parameter 100:

Number of stitches how long the puller lifts

Setting range:

0...400 stitches