Altering global parameters

Parameter 58:

Display of the software version

Parameter 59:

Number of stitches how long the seam chain is
sucked (seam beginning)

Input:

0 …50

Parameter 65:

Thread tension lift

Input:

0 …50

Parameter 79:

Soft start after “Stop in the seam”

Input:

0 …500

6.4.3

Input - Output test

Via the input - output test the different input and output elements can
be checked.

Input test

Press key “P”.

Press key “8”.

Actuate the corresponding input.
Example:
Cover the light barrier.

Press key “Program stop”.
The program is quitted.

Input elements

Switch

Designation

01

Light barrier 01 start

05

Switch “Program stop”

06

Mouse back

11

Potentiometer needle feed and differential bottom feed
(optional equipment)

12

Potentiometer puller (optional equipment)

34