Comtech EFData Documentation Update

Subject:

Changes to Chapter 3 (Communications Link Jumper Setting)

Date:

July 28, 1997

Document:

RSU-503 Redundancy Switch Unit Installation and Operation
Manual, Rev. 8, dated April 4, 1997

Part Number:

MN/RSU503.EA8

Collating Instructions:

Attach this page to page 3-1

Comments:

The following changes provide the correct information for jumper placement when choosing
between RS-232 or -485. This information will be incorporated into the next revision.

Change Specifics:

3.4.1 Communications Link

The terminal functions can be remotely controlled and monitored via an RS-485 or RS-232
communications link.

The RS-485 interface makes it possible to operate 255 terminals on a common communications
link.

The RS-232 interface is used to communicate with a single terminal.

The M&C module must be hardware configured on the M&C board to one of the two interfaces. Refer to
the following table for jumper placement at JP1:

RS-485

Configuration

RS-232

Configuration

1-2

9-10

3-4

11-12

5-6

13-14

7-8

15-16