2 internal indicators – Comtech EF Data RSU-503 User Manual

Page 47

Advertising
background image

Maintenance

RSU-503 Redundancy Switch Unit

4–2

Rev. 8

4.2 Internal Indicators

The switch does not have any external indicators. The internal indicators (shown in
Figure 4-1) are not normally used by the operator. However, if the switch must be
opened, descriptions of the indicators are provided in the following table.

Indicator

LED

Cause

System Status

PWR A

Green

Illuminates if RFT A power is available.

PWR B

Green

Illuminates if RFT B power is available.

32V

Green

Illuminates when power available to switches.

SUM FLT

Red

Illuminates an ambiguity failure, RFT fault, or power supply
fault.

Uplink

FLT A

Red

Illuminates with failure of unit A uplink.

FLT B

Red

Illuminates with failure of unit B uplink.

FLT AMB

Red

Illuminates if uplink switch indicators do not agree.

B OL

Yellow

Illuminates when unit B uplink is online.

MAN

Yellow

Illuminates when uplink is in manual mode.

Downlink

FLT A

Red

Illuminates with failure of unit A downlink.

FLT B

Red

Illuminates with failure of unit B downlink.

FLT AMB

Red

Illuminates if downlink switch indicators do not agree.

B OL

Yellow

Illuminates when unit B downlink is online.

MAN

Yellow

Illuminates when downlink is in manual mode.

Figure 4-1. LED and Switch Locations