B.2.1 start character, B.2.2 device address – Comtech EF Data RSU-503 User Manual

Page 64

Advertising
background image

RSU-503 Redundancy Switch Unit

Remote Control Operation

Rev. 8

B–3

The general message structure is as follows:

Start Character

Device Address

Command/Response

End of Message Character

B.2.1 Start Character

A single character precedes all messages transmitted on the remote link. This character
flags the start of a message. This character is:

“<”

for commands

“>”

for responses

B.2.2 Device Address

The device address is the address of the switch which is designated to receive a transmitted
command, or which is responding to a command.

Valid device addresses are 1 to 3 characters long, and in the range of 1 to 255. Address 0 is
reserved as a global address which simultaneously addresses all devices on a given
communications link. Devices do not acknowledge global commands.

Each switch and RFT connected to a common remote communications link, must be
assigned its own unique address. Addresses are software selectable at the unit, and must be
in the range of 1 to 255.

Note: Global address “*” is reserved for KP-10 (the external keypad) commands. Refer
to the KP-10 External Keypad Installation and Operation Manual.