4 m&c (j4, j8) – Comtech EF Data RSU-503 User Manual

Page 34

Advertising
background image

Installation

RSU-503 Redundancy Switch Unit

18

Rev. 8

2.4.4 M&C (J4, J8)

The M&C connectors are used to interface with Units A and B, respectively. Included on
these connectors are:

Nine RS-232/485 communication pins (A to J)

Switch power (L)

Fault reporting

The M&C connectors are 26-pin circular female connectors, with the following pinouts:

Pin #

Name

Function

RS-232

RS-485

A

GND

-RX/TX

B

-RX/TX

C

+RX/TX

D

CTS

+RX/TX

Clear to Send

E

TD/TX

Transmit Data

F

RTS

Ready to Send

G

RD/RX

Receive Data

H

DSR

Data Set Ready

J

GND

Ground

K

LNA POWER

10V to LNA

L

EXT POWER

Input Voltage, 11V, 1A max.

M

EXT FLT IN

Fault Input from TWT

N

Reserved

P

N/C

R

GND

Ground

S

Chassis Ground

Ground

T

Reserved

U

UL FLT NC

Fault relay input, closes with Uplink fault

V

UL FLT COM

Fault relay input, COMMON

W

UL FLT NO

Fault relay input, opens with Uplink fault

X

DL FLT NC

Fault relay input, closes with Downlink fault

Y

DL FLT COM

Fault relay input, COMMON

Z

DL FLT NO

Fault relay input, opens with Downlink fault

a

LNA RTN

Ground return from LNA

b

Reserved

c

Reserved

Notes:

1. Clear to Send (CTS) is tied to Ready to Send (RTS) in RS-232 mode.
2. RD/RX and TD/TX are switched in the switch in order to communicate with

the RFTs.

Advertising