B.3 switch redundancy commands/responses, B.3.1 rft commands/responses, B.3.2 configuration commands/responses – Comtech EF Data RSU-503 User Manual

Page 66

Advertising
background image

RSU-503 Redundancy Switch Unit

Remote Control Operation

Rev. 8

B–5

B.3 Switch Redundancy Commands/Responses

B.3.1 RFT Commands/Responses

For information on remote control operation of the two individual RFT units, refer to the
remote control operation specification in the RFT Radio Frequency Terminal Installation
and Operation Manual.

B.3.2 Configuration Commands/Responses

The following commands control the redundancy configuration and its operating modes.

Redundant
System
Address
Selection

The following messages are addressed to the switch (or
corresponding redundant RFT) and, if applicable, will be
reformatted before the transmission to the selected RFT.

These commands assign the addresses to the three units which
make up the redundancy system.

RFT A Address

Command
:
Response:

Status:
Response:

<add/ASA_XXX'cr'
>add/ASA_XXX'cr''lf']

<add/ASA_'cr'
>add/ASA_XXX'cr''lf']

Where:

XXX = 1 to 255. Default = 2.
add = Current address of the switch.
XXX = New address for unit A.

This command selects the address of RFT, unit A (RFT_A).

RFT B Address

Command
:
Response:

Status:
Response:

<add/ASB_XXX'cr'
>add/ASB_XXX'cr''lf']

<add/ASB_'cr'
>add/ASB_XXX'cr''lf']

Where:

XXX = 1 to 255. Default = 3.
add = Current address of the switch.
XXX = New address for unit B.

This command selects the address of RFT, unit B (RFT_B).

RSU-503
Address

Command
:
Response:

Status:
Response:

<add/ASR_XXX'cr'
>add/ASR_XXX'cr''lf']

<add/ASR_'cr'
>add/ASR_XXX'cr''lf']

Where:

XXX = 1 to 255. Default = 1.
add = Current address of the switch.
XXX = New address for the switch.

This command selects the address of the switch.

If the desired address is currently in use, the response will be:

>add/?ER_ADDRESS IN USE'cr''lf']

Advertising