B.3.3 status commands/responses – Comtech EF Data RSU-503 User Manual

Page 68

Advertising
background image

RSU-503 Redundancy Switch Unit

Remote Control Operation

Rev. 8

B–7

B.3.3 Status Commands/Responses

Lock Mode

Command
:
Response:

Status:
Response:

<add/LM_XX'cr'
>add/LM_XX'cr''lf']

<add/LM_'cr'
>add/LM_XX'cr''lf']

Where: XX = LK (lock) or EN (enable). Default = EN.

Lock mode prevents the current settings from being changed.

Uplink Switch
Config

Command
:
Response:

Status:
Response:

<add/ULS_X'cr'
>add/ULS_X'cr''lf']

<add/ULS_'cr'
>add/ULS_X'cr''lf']

Where: X = A or B.

This command is only applicable for the RSU-503L.

This command selects the uplink switch configuration, placing the
selected unit online, and the other on standby.

Uplink
Redundancy
Switch Mode

Command
:
Response:

Status:
Response:

<add/ULM_X'cr'
>add/ULM_YYYY'cr''lf']

<add/ULM_'cr'
>add/ULM_YYYY'cr''lf']

Where:

X = M (Manual) or A (Auto).
YYYY = MAN or AUTO.

This command places the switch uplink in either Manual or Auto
mode. In Auto mode, the switch will activate a switchover upon a
fault of the online unit.

Downlink
Switch Config

Command
:
Response:

Status:
Response:

<add/DLS_X'cr'
>add/DLS_X'cr''lf']

<add/DLS_'cr'
>add/DLS_X'cr''lf']

Where: X = A or B.

This command selects the downlink switch configuration, placing
the selected unit online, and the other on standby.

Downlink
Redundancy
Switch Mode

Command
:
Response:

Status:
Response:

<add/DLM_X'cr'
>add/DLM_YYYY'cr''lf']

<add/DLM_'cr'
>add/DLM_YYYY'cr''lf']

Where:

X = M (Manual) or A (Auto).
YYYY = MAN or AUTO.

This command places the switch downlink in either Manual or Auto
mode.

Hardware

Command
:
Response:

Status:
Response:

<add/HWC_X'cr'
>add/HWC_X'cr''lf']

<add/HWC_'cr'
>add/HWC_X'cr''lf']

Where: X = A (both Uplink and Downlink), B (Uplink only),
C (Downlink only), D (both Uplink and Downlink without LNA plate
- mask off DLA_FLT).

This command is used to configure the RSU for either "Uplink and
Downlink", "Uplink Only", or "Downlink Only" operation.

Switch
Initialization
Config

Command
:
Response:

Status:
Response:

<add/SWI_X'cr'
>add/SWI_X'cr''lf']

<add/SWI_'cr'
>add/SWI_X'cr''lf']

Where: X = A (UL/DL, last state on power-down) (default),
B (UL/DL A/A online), C (UL/DL B/B online), D (UL/DL A/B online),
E (UL/DL B/A online).

Note: Valid for all HWC configurations (see the HWC_ command).

This command is used to configure the switch online initialization
on power-up, and clears any ambiguity faults.

Redundancy
Operating
Status

Command
:
Response:

<add/ROS_'cr'
>add/ROS_'cr'
ULS_X'cr'
ULM_X'cr'
DLS_X'cr'
DLM_X'cr'
ASA_nnn'cr'
ASB_nnn'cr''lf']

Where:

X = A or B, uplink switches.
X = A (auto) or M (manual).
X = A or B, downlink switches.
X = A (auto) or M (manual).
nnn = 1 to 255, Unit A address.
nnn = 1 to 255, Unit B address.

This command returns a block of data from the switch, reflecting
the status of the current redundancy configuration.

Advertising