Theory of Operation

RSU-503 Redundancy Switch Unit

3–4

Rev. 8

Downlink

B4

B5

B6

B7

WR8000, B2

WR8000, B5

IF_A

RF_A

IF_B

RF_B

1= A ON LINE

0 = B ON LINE

1 = OKAY

0 = AMBIGUITY FAULT

0

0

0

0

1

0

0

0

0

1

1

0

0

0

1

0

1

0

0

0

1

1

1

1 - Valid state, A online

0

1

0

0

0

0

0

1

0

1

0

0

0

1

1

0

0

0

0

1

1

1

0

0

1

0

0

0

1

0

1

0

0

1

1

0

1

0

1

0

1

0

1

0

1

1

1

0

1

1

0

0

0

1 - Valid state, B online

1

1

0

1

0

0

1

1

1

0

0

0

1

1

1

1

0

0

3.4.3 Auto/Manual Modes

In Auto mode, switch-over can only occur as a result of a fault, as listed in the following
table:

RD9001

B0

B1

UL FLT A

UL FLT B

Fault Description

0

0

No faults.

0

1

Fault on B uplink, switch to uplink A, WR8001 B0.

1

0

Fault on A uplink, switch to uplink B, WR8001 B1.

1

1

Fault on both, do nothing. Monitor, and switch to the first
unit to remote the fault.

B2

B3

DL FLT A

DL FLT B

Fault Description

0

0

No faults.

0

1

Fault on B downlink, switch to downlink A, WR8001 B2.

1

0

Fault on A downlink, switch to downlink B, WR8001 B3.

1

1

Fault on both, do nothing. Monitor, and switch to the first
unit to remote the fault.

In Manual mode, the switch initiates the online pulses from only two sources:

Request from the MTI

Onboard push-button switches

In normal service with the cover secured, switch-over can occur only from an MTI
request.

Advertising