4.5.3 M&C Input/Output Signals (J17)

The M&C I/O connector is a 25-pin male D connector with the following pinouts:

Pin #

Name

Function

13

DC GND A

Tied to signal ground

25

DC GND B

Tied to signal ground

12

UL FLT COM A

Tied to signal ground

24

UL FLT COM B

Tied to signal ground

11

DL FLT COM A

Tied to signal ground

23

DL FLT COM B

Tied to signal ground

10

Spare

22

UL FLT NO A

Input, connected to ground when normal

9

UL FLT NC A

Input, connected to ground when faulted

21

UL FLT NO B

Input, connected to ground when normal

8

UL FLT NC B

Input, connected to ground when faulted

20

Spare

7

DL FLT NO A

Input, connected to ground when normal

19

DL FLT NC A

Input, connected to ground when faulted

6

DL FLT NO B

Input, connected to ground when normal

18

DL FLT NC B

Input, connected to ground when faulted

5

Spare

17

Spare

4

SUM FLT NO

Output, connected to COM when normal

16

SUM FLT COM

Output common

3

SUM FLT NC

Output, connected to COM with any fault

15

Spare

2

XVA

Input, DC power from unit A (approx. 11V)

14

Spare

1

XVB

Input, DC power from unit B (approx. 11V)