4 performance and operation limits – Flowserve APKD User Manual

Page 16

Advertising
background image

APKD DOUBLE-CASE, DOUBLE-SUCTION USER INSTRUCTIONS 26999903 07-13

Page 16 of 55

flowserve.com

3.3.7.1

High pressure stuffing box

This type of packing box is fitted on to an open lineshaft for pressures up to 20 bar (300 psi) uses six rings of
packing with one seal cage and allows grease lubrication.

Figure 3.10


3.3.8

Mechanical shaft seal

APKD’s can also be fitted with a mechanical seal.
The requirement to fit the mechanical seal to be
provided at the time of contract.

3.3.9 Accessories
Accessories may be fitted when specified by the
customer.

3.4 Performance and operation limits

This product has been selected to meet the
specifications of the purchase order. See section 1.5.

The following data is included as additional
information to help with the installation. It is typical
and factors such as temperature, materials and seal
type may influence this data. If required, a definitive
statement for your particular application can be
obtained from Flowserve.Operating limits

Pumped liquid temperature
limits*

5 ºC (40 ºF) to +80 ºC (176 ºF)

Maximum ambient
temperature*

Up to +40 ºC (104 ºF)

Maximum pump speed

refer to the nameplate

*Subject to written agreement from Flowserve.
Special designs and materials may be available for
pumps operating above and below these specified
limits. Contact Flowserve for upgrade options
available for your specific application.

Advertising