7 pump removal and disassembly – Flowserve M-series PolyChem User Manual

Page 37

Advertising
background image

USER INSTRUCTIONS PolyChem M-SERIES ENGLISH 71569218 07-11

flowserve.com

Page 37 of 60

®

P_4x3-10

Trim Diameter

Front Shroud

Diameter

mm

inch

mm

Inch

254.00

(10.000)

N/A

N/A

250.83

(9.875)

N/A

N/A

247.65

(9.750)

265.31

(10.445)

244.48

(9.625)

262.27

(10.325)

241.30

(9.500)

259.23

(10.206)

238.13

(9.375)

256.18

(10.086)

234.95

(9.250)

253.14

(9.966)

231.78

(9.125)

250.10

(9.847)

228.60

(9.000)

247.06

(9.727)

225.43

(8.875)

244.02

(9.607)

222.25

(8.750)

240.98

(9.487)

219.08

(8.625)

237.94

(9.368)

215.90

(8.500)

234.90

(9.248)

212.73

(8.375)

231.86

(9.128)

209.55

(8.250)

228.82

(9.009)

206.38

(8.125)

225.78

(8.889)

203.20

(8.000)

222.73

(8.769)

200.03

(7.875)

219.69

(8.649)

196.85

(7.750)

216.65

(8.530)

193.68

(7.625)

213.61

(8.410)

190.50

(7.500)

210.57

(8.290)

187.33

(7.375)

207.53

(8.170)

184.15

(7.250)

204.49

(8.051)

180.98

(7.125)

201.45

(7.931)

177.80

(7.000)

198.40

(7.811)

174.63

(6.875)

195.37

(7.692)

171.45

(6.750)

192.52

(7.580)

168.28

(6.625)

189.96

(7.479)

165.10

(6.500)

187.77

(7.393)

Notes:
Interpolate between shown dimensions for 1.57 mm (0.062 in.) trim
increments.

Figure 6-7: Group A and 1 pumps

Figure 6-8: Group B and 2 pumps

6.7 Pump removal and disassembly


a)

Before performing any maintenance, disconnect
the driver from its power supply and lock it off line.

Lock out power to driver to prevent

personal injury.

b)

Close the discharge and suction valves, and
drain all liquid from the pump.

c)

Close all valves on auxiliary equipment and
piping, then disconnect all auxiliary piping.

d)

Decontaminate the pump as necessary.

If Flowserve PolyChem M-series

pumps contain dangerous chemicals, it is important to
follow plant safety guidelines to avoid personal injury
or death.

Small amounts of liquid may be trapped in the

casing and/or containment area. Proper
decontamination is the responsibility of the user.

Drain and flush the pump before proceeding.

The PolyChem M-series pump is designed to handle
corrosive, toxic, and hazardous process fluids and
may need to be decontaminated prior to any
disassembly

Advertising