Pump not reaching design flow rate

Pump not reaching design head (TDH)

No discharge or flow with pump running

Pump operates for short period, then loses prime

Excessive noise from wet end

Excessive noise from power end

Pump exhibits increased or higher than anticipated power consumption

Pump exhibits decreased or lower than anticipated power consumption

PROBABLE CAUSES

POSSIBLE REMEDIES

Bearing damage due to improper
lubrication, identified by one or more
of the following:
1. Abnormal bearing temperature
rise.
2. A stiff cracked grease
appearance.
3. A brown or bluish discoloration of
the bearing races.

1. Be sure the lubricant is clean.
2. Be sure proper amount of lubricant is used. The constant level oiler
supplied with Flowserve pumps will maintain the proper oil level if it is
installed and operating properly. In the case of greased lubricated
bearings, be sure that there is space adjacent to the bearing into which it
can rid itself of excessive lubricant, otherwise the bearing may overheat
and fail prematurely.
3. Be sure the proper grade of lubricant is used.

Outer magnet assembly rubbing
bearing housing or containment
shell.

1. Check integrity of ball bearings.
2. Make sure drive shaft is not bent.
3. Make sure outer magnet assembly has not come unscrewed due to

incorrect motor rotation.