System Overview

Delivery or Dipstick Key Sequence

Page 24 MDE-4338A TopKAT™ Fuel Management System Operation Manual · February 2009

10

Proceed to dispense fuel. When you finish fueling your vehicle, turn off the dispenser handle
and return the nozzle to its holder. The transaction information is automatically recorded in the
system’s memory for later recall. The transaction information may also be printed on the data
terminal or logger.

Delivery or Dipstick Key Sequence

This is now available at Master and all on-line satellites. To enter into the Delivery or Dipstick
Key Sequence, proceed as follows:

1

Observe the selected idle message.
Note: In its idle state, the TopKAT LCD displays the selected idle message.

2

After completion of the delivery or to record a dipstick reading, insert the delivery or dipstick
key into the key receptacle and turn it clockwise.
The system responds ENTER TANK #.

3

Enter the appropriate tank number and press ENTER.
The system responds ENTER TANK QTY.

4

Enter the appropriate quantity and press ENTER.
The system responds QUAN. RECORDED TURN KEY LEFT, REMOVE.

5

Remove key.

Supervisor Key Sequence

To enter into the Supervisor Key Sequence, proceed as follows:

1

Observe the selected idle message.
Note: In its idle state, the TopKAT LCD displays the selected idle message.

2

Insert supervisor key into the key receptacle and turn it clockwise.
The system responds KEY #(0) or VEH # (1).

3

If you are entering a key number, press 0. The KEY # prompt appears.

~ OR ~

If you are entering a vehicle number; press 1. The VEH # prompt appears.

4

Enter the appropriate key or vehicle number and press ENTER.

At this point, the system follows its normal fueling sequence.